2026/06/26

synology Active Backup for Business虛擬機備份後 只還原特定檔案

 環境:

synology Active Backup for Business

備份整台虛擬機

異常狀況:

需要還原特定檔案,但不想花時間先還原整台虛擬機

解決過程:

在Active Backup for Business的確是只有整台虛擬機還原的選項。

但可以到Active Backup for Business Portal 裡面,在左上角可以選擇你備份的其中一台虛擬機。

畫面下方就會有時間軸讓你選擇備份的時間點,畫面中間就是每個磁區,你就可以點進去查看裡面所有的檔案,針對需要還原的檔案直接下載到本機中就行了。



Environment:

Synology Active Backup for Business
Virtual Machine Backup

Issue:

You need to restore specific files from a virtual machine backup, but you do not want to spend the time restoring the entire virtual machine first.

Resolution:

Although Active Backup for Business only provides an option to restore the entire virtual machine, you can restore individual files through Active Backup for Business Portal.

  1. Open Active Backup for Business Portal.
  2. In the upper-left corner, select the backed-up virtual machine.
  3. Use the timeline at the bottom of the page to choose the desired backup point.
  4. The center pane will display all the virtual disks.
  5. Browse the disks to locate the required files or folders.
  6. Download the selected files directly to your local computer.

This method allows you to restore individual files without having to restore the entire virtual machine first, saving both time and storage space.





2026/06/23

AD匯入admx

 AD裡GPO有些設定不在內建的選單中,但可以透過下載admx檔,增加要透過GPO派送的設定。

以m365 office為例,可以先去下載它的admx檔(https://www.microsoft.com/en-us/download/details.aspx?id=49030)。

下載的時後雖然只有英文版,但下載完,執行後,會將相關的檔案解壓縮在一個資料夾中。

裡面會有admx跟adml檔。

https://www.wisecleaner.com/think-tank/764-How-to-Install-ADMX-and-ADML-for-Microsoft-Edge-Group-Policy-Management.html

2026/06/17

windbg 查看 memory dmp檔

環境:

win11

windbg

異常狀況:

用windbg 開啟dmp檔,看不到裡面的log分析。

解決過程:

點選 command browser。

執行 !analyze -v ,就會出現記錄,可以查看是什麼原因造成系統異常。




2026/06/10

solidworks 按 del 鍵沒反應

環境:

solidworks

異常狀況:

del 鍵失效,在圖中對任何東西按下del鍵,都無法刪除,沒任何反應

解決過程:

solidworks內對刪除的快速鍵設定不見造成此問題。

從"工具" ->"自定"->"鍵盤",裡面會有"刪除"的快速鍵可以設定,這邊選擇del鍵,就可以恢復del鍵的刪除功能。


Environment:

SolidWorks

Issue:

The Delete (Del) key stops working.
Pressing the Del key on any object within a drawing or model has no effect, and nothing is deleted.

Resolution:

The issue is caused by the Delete keyboard shortcut assignment being removed or changed within SolidWorks.

To restore the Delete key function:

  1. Go to Tools → Customize.
  2. Select the Keyboard tab.
  3. Locate the command Delete.
  4. Assign the Del key as its keyboard shortcut.
  5. Apply the changes.

After reassigning the shortcut, the Del key will function normally and can be used to delete objects again.

2026/06/09

commvault Alert: Index State Type: Custom Rules - Index State

   環境:

commvault


異常狀況:

突然每天都會收到這個警告信,但備份工作都正常,不知是哪邊有問題。

後來發現這個backupset底下的所有虛擬機備份,在這警告信出現前的備份都可以正常還原。

在開始發出警告信後的備份,還原時都會出現錯誤:Could not perform the operation as Log restore failed for Job 161471. Please check Index Server log for more details。




解決過程:

參考ai上的作法,在commvault主機上的C:\Program Files\Commvault\ContentStore\IndexCache,底下有CvIdxDB跟CvIdxLogs資料夾

在裡面找到跟上面DbName相同名稱的資料夾,把他們改名。

重新建立還原工作,系統就會重建裡面的內容,恢復正常~~但試過沒用。

後來重新啟動完整備份,還是一樣的錯誤。

最後解法就是,建一個新的backupset,在裡面對虛擬機建立新的備份工作,備份完測試,可正常還原。


Environment:

Commvault

Issue:

An alert email suddenly started appearing every day, although all backup jobs were completing successfully and no obvious issues were found.

Further investigation showed that:

  • Backups of all virtual machines under this Backupset that were created before the alert emails started could be restored normally.

  • Backups created after the alerts began failed during restore with the following error:

Error:
Could not perform the operation as Log restore failed for Job 161471. Please check Index Server log for more details.

Troubleshooting Process:

Based on suggestions found online, the following method was attempted:

  1. On the Commvault server, navigate to:
    C:\Program Files\Commvault\ContentStore\IndexCache

  2. Locate the folders under CvIdxDB and CvIdxLogs that have the same name as the DbName shown in the error.

  3. Rename those folders.

  4. Create a new restore job so the system can rebuild the index data.

However, this method did not resolve the issue.

A Full Backup was then executed again, but the restore error still occurred.

Final Resolution:

The issue was resolved by:

  1. Creating a new Backupset.

  2. Creating a new backup job for the virtual machines within that Backupset.

  3. Running the backup again.

After the new backup completed, restore tests were performed and the restore worked normally.

2026/06/03

安裝win11 抓不到pcie ssd硬碟。

 環境:

acer主機

Intel 13代 cpu

pcie ssd

異常狀況:

安裝win11,一直抓不到ssd硬碟。

上acer官網找到了irst的驅動,安裝時這個驅動也不支援,還是找不到硬碟。

上intel官網抓到最新一代的irst驅動,卻是exe檔,在win11安裝過程,也沒辦法安裝

解決過程:

intel官網抓到最新一代的irst驅動是exe檔,需在其他台電腦,用powershell指令,去解壓縮,裡面就會有driver這個資料夾。

安裝win11時就可以透過裡面的檔案,載入pcie ssd。


  1. 在包含SetupRST.exe檔的目錄中打開終端,方法是右鍵按兩下目錄並在此處選擇「在終端中打開」或「打開 PowerShell」。您可能必須在目錄上按 SHIFT 鍵,才能看到要選擇的正確選項。
  2. 透過執行命令 ./SetupRST.exe -extractdrivers SetupRST_extracted解壓縮預安裝驅動程式

Environment:

Acer desktop/laptop
Intel 13th Gen CPU
PCIe SSD

Issue:

During Windows 11 installation, the SSD drive is not detected.

The Intel Rapid Storage Technology (IRST) driver downloaded from the Acer support website was loaded during setup, but the SSD still could not be detected.

A newer IRST driver was found on Intel's website, but it was provided as an .exe installer, which cannot be installed directly during the Windows 11 installation process.

Resolution:

The latest Intel IRST package downloaded from Intel's website must first be extracted on another computer.

  1. Download the latest SetupRST.exe from Intel.
  2. Open a terminal (PowerShell or Command Prompt) in the folder containing SetupRST.exe.
  3. Run the following command:
.\SetupRST.exe -extractdrivers SetupRST_extracted

This will extract the pre-installation drivers into a folder named SetupRST_extracted.

To open a terminal in the correct folder:

  • Right-click within the folder and select "Open in Terminal" or "Open PowerShell window here".
  • On some Windows versions, you may need to hold the SHIFT key while right-clicking to see the appropriate option.
  1. Copy the extracted driver files to the Windows 11 installation USB drive.
  2. During Windows 11 setup, select Load Driver when choosing the installation disk.
  3. Browse to the extracted driver folder and load the IRST driver.

After loading the extracted driver, the PCIe SSD will be detected and Windows 11 installation can proceed normally.

2026/06/01

MS SQL 維護計劃 備份到NAS共用資料夾

環境:

AD

NAS

MS SQL

異常狀況:

MS SQL 維護計劃 在設定DB備份的路徑,不能指定到NAS上的共用資料夾。

解決過程:

維護計劃在備份時,執行的身份通常是預設的一個系統服務帳號,可以到"服務"去查。

因為沒辦法在NAS上的共用資料夾上指派存取權限給這個帳號。

所以要換個方法

1.先在AD建立一個群組,然後把MS SQL這台主機的電腦帳號,加到這個群組。

2.接著在NAS上的共用資料夾,指派AD群組有修改權限。

這樣就完成了,備份時,這台主機就直接有權限讀寫,不會被SQL服務執行的身份給影響。


Environment:

Active Directory (AD)
NAS
Microsoft SQL Server

Issue:

When configuring a database backup destination in an MS SQL Server Maintenance Plan, the backup cannot be written directly to a shared folder on a NAS.

Resolution:

When a Maintenance Plan runs, it typically executes under the security context of a SQL Server service account (which can be identified in Services).

Since it is often not possible to assign permissions on the NAS shared folder directly to this service account, the following approach can be used:

  1. Create a new Active Directory security group.
  2. Add the computer account of the SQL Server to this AD group.
  3. On the NAS shared folder, grant the AD group Modify permissions.

With this configuration, the SQL Server host can access the shared folder using its computer account permissions, allowing the Maintenance Plan to read from and write to the NAS share without being affected by the specific SQL Server service account being used.

2026/05/26

Backup exec 備份MS SQL時 只能完整備份

 環境:

Backup exec 

Commvault

MS SQL

異常狀況:

Backup exec 備份MS SQL時,,設定差異備份,還是只會執行完整備份

解決過程:

Commvault 虛擬機備份設定中,如果選擇了File System and Application Consistent,就會把之前Backup exec 對MS SQL備份的備份鏈資訊重置,造成Backup exec之後備份必須做完整備份。

所以要把Commvault 虛擬機備份設定改成下面的Crash Consisten



Environment:

Backup Exec
Commvault
Microsoft SQL Server

Issue:

When using Backup Exec to back up MS SQL Server, the job is configured for Differential Backup, but it always performs a Full Backup instead.

Resolution:

In the Commvault virtual machine backup settings, if “File System and Application Consistent” is enabled, it resets the SQL backup chain information previously created by Backup Exec.

As a result, Backup Exec is forced to perform a new Full Backup before Differential Backups can continue.

To avoid this issue, change the Commvault VM backup setting from:

  • File System and Application Consistent

to:

  • Crash Consistent


2026/05/18

M365 Outlook 寄信時 簽名檔 內的圖檔變成附件

環境:

m365 office

異常狀況:

突然有愈來愈多使用者寄出的信件,在收件人的outlook, 簽名檔 內的圖檔會破圖,如下圖,裡面會寫"無法顯示連結的影像。檔案可能已移動.............",然後那個圖會變成附件



解決過程:

比對後發現,因為m365 office會自動更新,有些更新到最新的outlook,才會有這種問題。

然後在去檢查,才發現是圖片如果有設定成"文繞圖",這個圖變成附件。

只要把"文繞圖"改成"與文字排列"就沒問題了


後來m365 office自己也把那個問題處理掉了。

版本 2605 (建置 20026.20140)

解決的問題

Word

  • 修正了在經典 Outlook 中使用 上下 文字換行時圖片無法顯示的問題。


Environment:

Microsoft 365 Office / Outlook

Issue:

An increasing number of users suddenly found that images in their email signatures were broken when viewed by recipients in Outlook.

The image area displayed the message:

“The linked image cannot be displayed. The file may have been moved…”

The image would also appear as an attachment in the email.

Resolution:

After comparison and testing, it was found that the issue only occurred on systems updated to the newer versions of Outlook through Microsoft 365 automatic updates.

Further investigation showed that the problem occurs when the signature image is configured with a text wrapping option.

If the image wrapping style is changed from “Wrap Text” to “In Line with Text”, the issue is resolved and the image displays normally in the email signature.

2026/05/14

Backup exec 2014 無法正常啟動

 環境:

windows 2012

backup exec 2014

異常狀況:

windows 2012 做完windows update,安裝完backup exec 2014,執行都會出現錯誤訊息,無法使用

Backup exec 啟動時跳出錯誤,必須直接關閉

問題事件名稱: CLR20r3 

問題簽章 01: BackupExec.exe 

問題簽章 02: 14.1.1786.0 

問題簽章 03: 5371d883 

問題簽章 04: mscorlib 

問題簽章 05: 4.8.4110.0 

問題簽章 06: 5de6dafa 

問題簽章 07: 113a



解決過程:

因為windows 系統在做更新時,裝了frameworks4.8,需要把它移除後,backup exec才能運作。

可參考官網說明

 https://www.veritas.com/support/en_US/article.100055701

卸载 .NET Framework 4.8 并重新启动服务器。此更新将在已安装的更新列表中显示为 KB4486105 (Windows 2012 R2)、KB4486081 (Windows 2012)、KB4486129 (Windows 2016)、KB4486153 (Windows 2019)。



Environment:

Windows Server 2012
Backup Exec 2014

Issue:

After installing Windows Updates on Windows Server 2012 and then installing Backup Exec 2014, Backup Exec fails to start and immediately crashes with an error message.

Error details:

  • Problem Event Name: CLR20r3
  • Application Name: BackupExec.exe
  • Application Version: 14.1.1786.0
  • Fault Module Name: mscorlib
  • Fault Module Version: 4.8.4110.0

Backup Exec displays an error on startup and must be closed immediately.

Resolution:

The issue is caused by Windows Update installing .NET Framework 4.8, which is incompatible with Backup Exec 2014.

Removing .NET Framework 4.8 and rebooting the server allows Backup Exec to function normally again.

Reference:
https://www.veritas.com/support/en_US/article.100055701?utm_source=chatgpt.com

The .NET Framework 4.8 update may appear in Installed Updates as:

  • KB4486105 (Windows 2012 R2)
  • KB4486081 (Windows 2012)
  • KB4486129 (Windows 2016)
  • KB4486153 (Windows 2019)


2026/05/11

HUKE HK100藍牙折疊鍵盤

在淘寶找了一個折疊鍵盤搭配平板使用。
HUKE HK100,折起來大概比手掌還大一點點,轉軸的地方還行,但沒到很扎實。
用起來都蠻順的,旁邊數字鍵功能都沒啟用,就當滑鼠用而已。
缺點大概就是按鍵上沒有注音符號。
出門帶平板加折疊鍵盤,比帶一台筆電還方便。




 

2026/04/29

COMMCAULT DR備份 Error Code [34:53] [34:53]

環境:

COMMCAULT

異常狀況:

存放DR備份的網路資料夾密碼有變更,之後DR備份就會有錯誤訊息

Error Code [34:53] [34:53] 

Failure Reason CommServeDR: Destination Directory [\\sharefolder\commvault\CVDRBackup] does not exist or is inaccessible 

CommServeDR: Destination Directory [\\sharefolder\commvault\CVDRBackup] does not exist or is inaccessible 



解決過程:

到commvault console裡的"控制台",找到"DR Backup",裡面可以變更網路資料夾的帳號與密碼,修改正確後就可以正常備份。



2026/04/27

環境:

WIN11 25h2

Logitech meet up視訊設備

異常狀況:

使用Teams,或其他網頁,搭配內建的喇叭/麥克風,功能正常。

Logitech meet up的喇叭/麥克風,就會失效,Teams還會跳出錯誤提示。





解決過程:

查看event log,會看到錯誤訊息

失敗的應用程式名稱: AUDIODG.EXE,

版本: 10.0.26100.8246,

時間戳記: 0x923cfbc9 

錯誤模組名稱: igo_src.dll,

 版本: 3.0.0.0,時間戳記: 0x642f89de 

例外狀況代碼: 0xc0000005 

錯誤位移: 0x000000000001d019 

錯誤處理常式識別碼: 0x788 

失敗的應用程式開始時間: 0x1DCD6189BA1A78A 

Faulting 應用程式路徑: C:\WINDOWS\system32\AUDIODG.EXE Faulting 

模組路徑: C:\WINDOWS\System32\DriverStore\FileRepository\igoapo.inf_amd64_50fe8789ddef31f8\igo_src.dll

這個錯誤關鍵是明顯音效處理模組故障,不是羅技設備本身壞掉。

最快的方式就是把內建的喇叭/麥克風的驅動程式移除,改裝舊一點的驅動,就正常了。


Environment:

Windows 11 25H2

Logitech Meetup video conferencing device


Issue:

When using Teams or web applications with the built-in speaker/microphone, everything works normally.

However, when switching to the Logitech Meetup speaker/microphone, the audio devices fail, and Teams shows an error message.


Investigation:

In Event Viewer, the following error can be found:

Faulting Application Name: AUDIODG.EXE

Faulting Module Name: igo_src.dll

Exception Code: 0xc0000005

Module Path: C:\Windows\System32\DriverStore\FileRepository\igoapo.inf...\igo_src.dll

This indicates a failure in the audio processing module (APO) rather than a hardware issue with the Logitech device itself.


Resolution:

The root cause is related to the built-in audio driver.

By:

Uninstalling the current built-in speaker/microphone driver

Installing an older (stable) version of the audio driver


The issue is resolved, and the Logitech Meetup device functions normally again.

2026/04/22

M365 office 的出現錯誤 : Symmetric Key Derivation Function version 'KDFV1' is invalid

環境:

M365 office

異常狀況:

OUTLOOK開啟會出現下列錯誤,

解決過程:

進到windows的"設定"->"帳戶"->"存取公司或學校資源"。

把裡面不需要的帳戶全部中斷連線,重新開啟outlook,就可以正常登入使用了。


Environment:

Microsoft 365 Office / Outlook

Issue:

When opening Outlook, an error message appears and Outlook cannot be used normally.

Resolution:

  1. Open Windows Settings
  2. Go to Accounts → Access work or school
  3. Disconnect all unnecessary accounts listed there
  4. Reopen Outlook

After removing the unused accounts, Outlook should log in and function normally again.


2026/04/21

國際牌冷氣 無線控制模組 CZ-T007 設定

1.  CZ-T007 先安裝到冷氣機上,安裝時,冷氣機無需斷電。

2.  搖控器拔掉電池,然後按住"溫度上跟下鍵",裝上電池,看到搖控器顯示 "31 bu"的畫面時,放掉上下鍵。

3. 按下"下鍵",畫面會顯示 "31SA"

4. 開啟手機中安裝的Panasonic IOT app。

5. 選擇"新增裝置",選擇無線模組。

6. 照app上的操作,先開啟手機的wifi功能,連上這個無線模組的WIFI,然後再輸入家中的wifi帳號/密碼。

7. 這樣就新增成功了,但要記住,搖控器不能改回原本的樣子了,就保持在"31SA"這個模式下,這時搖控器畫面雖然不會顯示其他的東西,但開關機的功能還是可以用,其他的就在手機上操作。

如果搖控器改回原本的操作模組,無線模組就會無法使用。

2026/04/08

 環境:

commvault

掛載nas共用資料夾,當作媒體櫃,存放備份資料。

異常狀況:

nas密碼變更後,commvault無法掛載共用資料夾

解決過程:

在控制台,裡面有credentials manager,裡面有目前使用的帳號密碼設定,可以從這邊去修改。



ESXI 變更密碼 失敗 - 發生一般系統錯誤: Weak password: is based on the old one. *** passwd: Authentication token manipulation error

 環境:

esxi

異常狀況:

無法變更,會出現錯誤

解決過程:

在系統裡的進階設定,裡面有一個Security.PasswordQualityControl 參數。

在裡面加入 similar-permit ,存檔後馬上生效,就可以變更密碼了。







2026/03/27

使用LDAP與AD連線出現異常

 環境:

win2025 AD

異常狀況:

PHP程式要用LDAP協定,透過domain name抓ad使用者資料,時好時壞,改用IP連線也是。

連到不用的DC主機都會有狀況。

解決過程:

DC主機上的本機安全性原則中,在"電腦設定->windows設定->安全性設定->網域控制站:LDAP伺服器簽署要求強制執行",要設定成停用,每台DC都要設定成停用,就可以排除問題。


Environment:

Windows Server 2025 Active Directory

Issue:

A PHP application uses the LDAP protocol to query AD user information via the domain name, but the connection is unstable (intermittently works and fails).
Using the DC’s IP address shows the same issue.

The problem occurs when connecting to certain domain controllers.

Resolution:

On the domain controllers, modify the Local Security Policy:

  • Go to:
    Computer Configuration → Windows Settings → Security Settings → Domain Controller: LDAP server signing requirements
  • Set it to Disabled

This setting must be applied to all domain controllers.

After applying the change, the issue is resolved.


2026/03/26

Commvault 備份虛擬機 突然變的很慢

環境:

Commvault 備份虛擬機

異常狀況:

對新的虛擬機做第一次備份,可能容量比較大,過程中又有其他的備份,造成效能問題,最後就停住多個小時後,手動取消。

但後來要重新備份時,傳輸速度變超級慢,速度大概只剩之前的1/7~8,重開機也一樣。

解決過程:

後來發現之前備份失敗後,虛擬機上有一份snapshot沒被移除,先在esxi上,把那份snapshot刪除後,重新備份,就正常了。



Environment:

Commvault (VM Backup)

Issue:

When performing the first backup of a new virtual machine, the data size was relatively large. During the process, other backup jobs were also running, causing performance issues. Eventually, the job became unresponsive and was manually canceled after several hours.

After that, when attempting to run the backup again, the transfer speed became extremely slow, dropping to about 1/7–1/8 of the original speed. Restarting the system did not resolve the issue.

Resolution:

It was later discovered that after the failed backup, a snapshot remained on the virtual machine and was not removed.

By logging into ESXi and deleting the leftover snapshot, then running the backup again, the performance returned to normal.

2026/03/25

ESXI 無法開啟虛擬機器 xxx的電源。開啟模組 monitorloop 的電源失敗

  環境:

ESXI  

Synology active backup business

異常狀況:

用Synology active backup business備份的虛擬機,還原到其他esxi後,開機出現錯誤。



解決過程:

原機配置了較高的CPU與RAM,還原後,目的esxi上資源不足,無法開機,把虛擬機的CPU與RAM調低後,就可以正常開機


Environment:

ESXi
Synology Active Backup for Business

Issue:

After restoring a virtual machine using Synology Active Backup for Business to another ESXi host, the VM fails to power on and shows an error.

Resolution:

The original VM was configured with relatively high CPU and RAM.
After restoration, the target ESXi host did not have sufficient resources to support that configuration.

By reducing the VM’s CPU and RAM allocation, the virtual machine was able to power on normally.

2026/03/24

ESXI VMFS 增加容量失敗-無法變更主機組態。

 環境:

ESXI 6.7

異常狀況:

底層硬碟RAID擴充完一顆新硬碟後,要在ESXI上也對儲存區進行擴充。

在web console上操作,對著要擴充的datastore ,選擇"增加容量"。


再來選擇"擴充現有..........."。


第三步,要先在分割之前的圖,點選vmfs區塊,然後就會出現一個調整新增容量的設定,選擇要把新增的硬碟,擴充多少容量到vmfs中。


按下完成後,就會出現錯誤,試了很多次,擴充不同的容量,都一樣錯誤:

說明:延伸 VMFS 資料存放區範圍的容量

狀態:失敗 - 無法變更主機組態。

解決過程:

用指令的方式擴充,就成功了。



Environment:

ESXi 6.7

Issue:

After expanding the underlying RAID by adding a new disk, the datastore also needs to be extended in ESXi.

When performing the operation via the web console:

  1. Select the datastore and choose “Increase capacity”
  2. Then select “Expand existing…”
  3. In the partition layout screen, select the VMFS partition, and adjust how much of the newly added space should be allocated to VMFS

However, after clicking Finish, the following error occurs regardless of the size selected:

  • Description: Extend VMFS datastore capacity
  • Status: Failed – Unable to change the host configuration

Resolution:

Expanding the datastore using the command line (CLI) was successful.















2026/03/12

DHCP 設定匯出匯入

DHCP config export command

netsh dhcp server export d:\backup.txt all


DHCP config import command

 netsh dhcp server import d:\backup.txt all

2026/03/03

commvault 備份時會當機

  環境:

commvault

x3650m3

win2012

異常狀況:

已經運作多年的備份主機,突然開始在備份時會當機,備份比較大的資料才會當機,只是少量的就不會,不執行備份放一整個晚上也都沒問題。

當機後通常會進到藍底白字畫面,搜尋相關錯誤資訊,但未有任何進度就會直接重開機。

沒有memory dump檔,事件檢視器也沒有任何可參考的資訊,只會有意外當機的事項。

IMM 的log裡也沒有任何的異常。

raid程式裡,硬碟與raid卡都健康。

用內建的記憶體測試,正常。

解決過程:

關閉防毒->無效

調低備份的Maximum number of parallel data transfer operations->無效

關機拔電後重開->無效

拔掉六條記憶體擦一擦,只插回基本的兩條->無效

在找不到任何方法下,先把記憶體全部插回,再試試,居然就正常了....

但過了一週,又開始發生備份會當機的狀況,大概兩天後主機的raid跟pci就亮橘燈了。

更換raid卡後終於恢復正常。


Environment:

Commvault
IBM x3650 M3
Windows Server 2012

Issue:

A backup server that had been running normally for many years suddenly began crashing during backup operations.
The crash only occurred when backing up large amounts of data. Backups with small amounts of data completed normally, and the server could remain powered on overnight without issues if no backup jobs were running.

After the crash, the system usually entered a blue screen. When attempting to view the error details, the system rebooted before any useful information could be collected.

Additional observations:

  • No memory dump files were generated.

  • Event Viewer only recorded an unexpected shutdown with no useful details.

  • IMM logs showed no abnormalities.

  • RAID management reported that the disks and RAID controller were healthy.

  • The built-in memory diagnostic test passed without errors.

Troubleshooting Process:

  • Disabled antivirus → No effect

  • Reduced Maximum number of parallel data transfer operations in Commvault → No effect

  • Powered off the server and unplugged power before restarting → No effect

  • Removed six memory modules, cleaned them, and left only two installed → No effect

With no other solutions available, all memory modules were reinstalled again.
Unexpectedly, after reinstalling all the RAM, the system returned to normal operation and the backup jobs completed successfully.

However, about one week later, the backup server began to crash again during backup jobs.

After approximately two more days, the RAID and PCI indicator lights on the server turned orange.

The RAID controller was then replaced, and after replacing the RAID card, the system finally returned to stable operation and the backup crashes stopped.


2026/02/26

commvault備份虛擬機失敗 There are too many existing backup snapshots on virtual machine

 環境:

commvault

異常狀況:

備份失敗

錯誤碼: [91:148] 描述: There are too many existing backup snapshots on virtual machine [xx]. Backup snapshots are being cleaned up, but manual intervention may be required to ensure that all snapshots are removed. This may indicate that the storage is unable to keep up with the I/O activity of the virtual machine during a backup. Source: backupserver, Process: vsbkp 

解決過程:

主要是因為備份虛擬機時,會先建立快照,但因為備份程式當掉,當成快照沒被清除。

之後要再備份就會出現此錯誤。

這時就連上esxi,到該虛擬機的快照管理中,把快照"全部刪除",然後就可以正常備份了。


Environment:

Commvault

Issue:

Backup failed with the following error:

Error Code: [91:148]
Description:
There are too many existing backup snapshots on virtual machine [xx]. Backup snapshots are being cleaned up, but manual intervention may be required to ensure that all snapshots are removed. This may indicate that the storage is unable to keep up with the I/O activity of the virtual machine during a backup.
Source: backupserver
Process: vsbkp

Resolution:

This issue occurs because when backing up a virtual machine, the system first creates snapshots. However, if the backup process crashes or fails, the snapshots may not be removed properly.

When attempting the next backup, this error will appear.

To resolve the issue:

  1. Log in to the ESXi host.

  2. Open the Snapshot Manager for the affected virtual machine.

  3. Select Delete All snapshots.

After removing all snapshots, the backup should run normally again.

2026/02/25

SQL management tool連線時出現錯誤:此憑證鏈結是由不受信任的授權單位發出的

 

環境:

MS SQL2022


異常狀況:

SQL management tool連線時出現錯誤:此憑證鏈結是由不受信任的授權單位發出的


解決過程:

錯誤訊息「此憑證鏈結是由不受信任的授權單位發出的」是因為 SQL Server 2022 預設強制執行加密連線。

勾選下面的「信任伺服器憑證」選項,即可正常登入。




Environment:

MS SQL Server 2022

Issue:

When connecting using the SQL management tool, the following error appears:
“The certificate chain was issued by an authority that is not trusted.”

Resolution:

This error occurs because SQL Server 2022 enforces encrypted connections by default.

Enable the “Trust Server Certificate” option in the connection settings, and then you will be able to log in normally.



2026/02/23

SQL 2022安裝時卡住不動

環境:

MS SQL2022

Kaspersky endpoint security


異常狀況:

MS SQL2022安裝到一半停住很久,cpu跟ram的使用資源都不會動。


解決過程:

將Kaspersky endpoint security防護暫停後,就會繼續安裝過程,完成剛裝


Environment:

MS SQL Server 2022
Kaspersky Endpoint Security

Issue:

During the installation of MS SQL Server 2022, the setup process gets stuck for a long time.
CPU and RAM usage remain unchanged and the installation does not continue.

Resolution:

After temporarily disabling Kaspersky Endpoint Security protection, the installation process resumes and completes successfully.

2026/01/29

Synology 取消 "此裝置以後不需要驗證"

 環境:

Synology  NAS啟用 2FA的"此裝置以後不需要驗證",需要取消


解決過程:

管理者登入後,到使用者設定中,在該帳號底下,選擇"登出所有裝置",就會跳出說明,提醒這樣也會取消信任裝置。

之後同設備要登入時,就要輸入2FA的驗證碼。




Environment:

On a Synology NAS, 2FA is enabled and the option “Trust this device / Do not require verification on this device in the future” needs to be revoked.

Resolution / Steps:

  1. Log in as an administrator.

  2. Go to User settings.

  3. Under the target user account, select “Sign out of all devices”.

  4. A prompt will appear explaining that this action will also revoke trusted devices.

After this, when the same device logs in again, it will be required to enter the 2FA verification code.



2026/01/27

Backup exec 的資料庫備份

  環境:

Backup exec 2014


異常狀況:

想要透過Backup exec 本身的工具beutility.exe,把Backup exec 自己的設定db檔匯出到其他存放。

但執行beutility.exe指令時,都會先跳出一個警告視窗,因為無法設定用batch自動執行。





解決過程:

Backup exec 的主程式裡就有可以設定db檔定期匯出到預設資料夾的功能了,不需要額外用beutility.exe來執行。

在"組態與設定"->"Backup Exec設定",裡面有一個"資料庫維護",就可以設定排程來做這件事。




Environment:

Backup Exec 2014

Issue:

Attempting to use Backup Exec’s built-in tool beutility.exe to export the Backup Exec configuration database to another storage location.
However, when running beutility.exe, a warning dialog always appears, making it impossible to automate the process using a batch script.

Resolution / Workaround:

Backup Exec already provides a built-in feature to periodically export the database to a default folder, so there is no need to use beutility.exe.

In Configuration and Settings → Backup Exec Settings, there is a Database Maintenance option where you can configure a scheduled task to perform this database export automatically.


2026/01/23

python抓取元大rtd裡的欄位即時資料範例

 import xlwings as xw

import time


# 連接當前開啟的 Excel 檔案

wb = xw.Book('txf.xlsm')

sheet = wb.sheets['價格記錄']


while True:

    # 假設元大 RTD 資料在 A1 儲存格

    price = sheet.range('A2').value

    print(f"當前即時價格: {price}")


    # 根據需求設定取樣頻率 (例如每秒 1 秒)

    time.sleep(1)

2026/01/22

Windows 資料夾透過FASTCOPY同步到NAS共用資料夾 權限並沒有同步

 環境:

Windows 資料夾透過FASTCOPY,同步到NAS共用資料夾


異常狀況:

資料夾開始建立進行同步時,發現權限並沒有同步過去



解決過程:

研究了很久,發現測試的資料夾正常,正式要同步的資料夾會有問題。

原來是資料夾第一次在同步時,還沒全部完成前去查看資料夾權限時,不會是最後的結果,所以要等同步完再檢查,就會發現資料夾的ACL權限有全部同步過去了。




Environment:

Windows folders synchronized to a NAS shared folder using FastCopy.

Issue:

When the folder creation and synchronization start, the folder permissions (ACLs) do not appear to be synchronized to the NAS.

Resolution / Findings:

After extensive investigation, it was found that test folders behaved normally, while the production folders showed this issue.

The root cause is that during the initial synchronization, if you check the folder permissions before the sync process has fully completed, the permissions shown are not the final result.
Once the synchronization finishes completely and you recheck the folder permissions, you will see that the ACL permissions have been fully and correctly synchronized.