在用powershell把一些安全性log匯出成csv時,國字 都會變成問號,這時只要把最後匯出成csv的指令,後面在加個用utf8編碼的指令就可以正常顯示了。
原指令
Export-Csv d:\eventlog.csv
修正後
Export-Csv d:\eventlog.csv -NoTypeInformation -encoding utf8
在用powershell把一些安全性log匯出成csv時,國字 都會變成問號,這時只要把最後匯出成csv的指令,後面在加個用utf8編碼的指令就可以正常顯示了。
原指令
Export-Csv d:\eventlog.csv
修正後
Export-Csv d:\eventlog.csv -NoTypeInformation -encoding utf8
在WORD程式內,透過插入物件的功能,要插入一個PDF檔,卻跳出"此物件是使用程式Acrobat建立。您的電腦並未安裝此程式......請安裝Acrobat或確定已關閉Acrobat中任何的對話"
先確認PDF檔都是可直接用Acrobat PDF Reader開啟,WORD試著插入EXCEL物件也正常。
所以就決定先重裝Acrobat PDF Reader,結果就解決問題了。
When trying to insert a PDF file into a Word document using the "Insert Object" function, the following error message appears: "This object was created using the Acrobat program. This program is not installed on your computer. Please install Acrobat or make sure that all Acrobat dialog boxes are closed."
I confirmed that the PDF files could be opened directly using Acrobat Reader. I also tried inserting an Excel object into a Word document, and that worked fine.
Based on these findings, I decided to reinstall Acrobat Reader. After doing so, the problem was resolved.
近期買的筆電在用HDMI連接會議室投影機時,都會顯示沒有連接到設備,接D-SUB卻正常投影。其他舊筆電兩種連接方式都正常。
本來以為是中間有連接一些轉接頭的關係,後來才發現,是因為新筆電解析度很高,但投影機的太低,如果接上投影機時,是在"同步顯示"的狀態下,投影機的畫面就無法投影,要改成"僅第二個螢幕顯示",或是把筆電的解析度降低,就可以正常投影了。
Recently purchased laptops using HDMI to connect to the projector will display "No device connected". D-SUB can be connected normally. Other old laptops can connect normally in both ways.
At first, I thought it was because of the adapters in the middle. Later, I found out that it was because the new laptop has a high resolution, while the projector is old and has a low resolution. If the projector is connected in "Synced display" mode, the projector's image cannot be projected. You need to change to "Only second monitor display" or lower the laptop's resolution to be able to project normally.
有一台linux主機在重開機後要重新mount其他機器的分享資料夾,執行執令後,畫面上沒任何反應。
過了一下子才會出現 mount.nfs input/output error,這是因為 /etc/init.d/portmap 這個服務沒有啟動的關係,
先 執行/etc/init.d/portmap status, 確認該服務是stop。
接著用執行啟用的指令/etc/init.d/portmap start,就可以再執行mount的動作了。
A Linux host fails to mount a shared folder from another machine after a reboot. After executing the mount command, the screen is blank.
After a while, an error message "mount.nfs input/output error" appears. This is because the service "/etc/init.d/portmap" is not running.
First, execute the command "/etc/init.d/portmap status" to confirm that the service is stopped.
Then, execute the command "/etc/init.d/portmap start" to start the service. After that, you can mount the shared folder again.
在新建虛擬機,從esxi要匯入一個 ova檔時,最後一步出現錯誤:硬體系列 vmx-18 不受支援
When creating a new virtual machine, an error occurs in the last step when importing an ova file from ESXi: "Hardware series vmx-18 is not supported."
The reason for this error is that the ova was created with a newer version of ESXi and is now being imported to an older version of ESXi, which does not support the vmx-18 hardware series. The solution is to upgrade ESXi to a version that supports the vmx-18 hardware series.
將KESS升級到最新版後,連同Network Agent也一起更新到14版。
裝好後卻一直無法跟中控台連線,測了一下發現是Network Agent 有啟用,但連不到中控台。
原來是Network Agent 14版不支援比較舊的作業系統了,規格可參考下列的kaspersky官網說明
https://support.kaspersky.com/KSC/14.2/en-US/255797.htm
After upgrading KESS to the latest version, the Network Agent were also updated to version 14.
After installation, the connection to the central console was not possible. Testing revealed that the Network Agent were running, but could not connect to the central console.
It turned out that Network Agent version 14 no longer supports older operating systems. The specifications can be found in the following Kaspersky website documentation:
https://support.kaspersky.com/KSC/14.2/en-US/255797.htm
筆電突然無法收音,但裝置都還在。
重上驅動也沒用。
可以換個帳號登入試試,有時後是profile的問題,如果換個帳號登入,麥克風是正常的,重把有問題的使用者profile重建即可。
The Windows10 laptop microphone suddenly stopped working, but the device is still there.
Reinstalling the driver did not work.
You can try logging in with a different account. Sometimes it is a profile issue. If the microphone works normally when you log in with a different account, you can rebuild the user profile with the problem.
Office突然不能用,無法移除,安裝也跳這個錯誤1402的錯誤。
雙買只有明顯趨勢下才能賺,雙賣是一有趨勢就慘了。
價差單也差不多,看你怎麼組,也是有上面的問題,怎麼做都不順。
追蹤一個長期獲利的雙賣交易者對帳單,是用大口數來產生比較好的收益,如果只看單口的獲利,可能都不到50塊,過程中要一直調整部份,這個實在難做。
趨勢就是這樣,做賣方,他就很愛動,做買方就不太動,總是常在小賠,偶爾小賺一點點,期望值依然是負的,所以還是先暫停吧,專心做買方當沖。
OCS Inventory 是一套免費的資產盤點軟體。
在使用的時後,會發現,同一台電腦會重複多次,這樣就會造成軟體盤點數量不準。
明明只有裝1套,但因為該台電腦重覆了3次,就會以為是裝了3套。
可以在"Manage"-->"Duplicates"功能中,設定要用什麼條件把重覆的電腦合併。
裡面已經有幾個定義好的,想要用哪個,就去點選後面的數字。
進去後可以看到列出的清單,每個都可以點開,看到相關的電腦資訊,看要合併哪一個,就打勾,選好後,最下面有一個merge的按鈕,按下去系統就會把重覆的合併。